Journal of Electromyography and Kinesiology
Volume 20, Issue 3 , Pages 542-549 , June 2010

A wavelet-based adaptive filter for removing ECG interference in EMGdi signals

  • Choujun Zhan

      Affiliations

    • Department of Electronic Engineering, City University of Hong Kong, Hong Kong, China
  • ,
  • Lam Fat Yeung

      Affiliations

    • Department of Electronic Engineering, City University of Hong Kong, Hong Kong, China
    • Corresponding Author InformationCorresponding author.
  • ,
  • Zhi Yang

      Affiliations

    • School of Information Science and Technology, Sun Yat-Sen University, Guang Zhou, China

Received 23 March 2009 ,Revised 27 May 2009 ,Accepted 22 July 2009.

References 

  1. Akkiraju P, Reddy DC. Adaptive cancellation technique in processing myoelectric activity of respiratory muscles. IEEE Trans Biomed Eng. 1992;39(6):652–655
  2. Carre P, Leman H, Fernandez C, Marque C. Denoising of the uterine EHG by an undercimated wavelet transform. IEEE Trans Biomed Eng. 1998;45(9):1104–1113
  3. Deng Y, Wolf W, Bullemer F. Time frequency analysis of diaphragmatic electromyogram for the detection of diaphragm fatigue. In: Proceeding of the 20th Annual International Conference of the IEEE Engineering and Biology Society. vol. 20, No. 6; 1998. p. 3010–27.
  4. Deng Y, Wolf W, Schnell R, Appel U. New aspects to event-synchronous cancellation of ECG interference: an application of the method in diaphragmatic EMG signals. IEEE Trans Biomed Eng. 2000;47(9):1177–1184
  5. Donoho D. Ideal spatial adaptation via wavelet shrinkage. Biometrika. 1994;81(3):425–455
  6. Donoho D. De-noising by soft-thresholding. IEEE Trans Inform Theory. 1995;41(3):612–627
  7. Drake JDM, Callaghan JP. Elimination of electrocardiogram contamination from electromyogram signals: an evaluation of currently used removal techniques. J Electromyogr Kinesiol. 2006;16(2):175–187
  8. Duiverman ML1, Eykern van LA, Vennik PW, Koeter GH, Maarsingh EJ, Wijkstra PJ. Reproducibility and responsiveness of a non-invasive EMG technique of the respiratory muscles in COPD patients and in healthy subjects. J Appl Physiol. 2004;96(5):1723–1729
  9. Gross D, Grassino A, Ross WRD, Macklem PT. Electromyogram pattern of diaphragmatic fatigue. J Appl Physiol. 1979;46(1):1–7
  10. Grossman A, Morlet J. Decomposition of hardy function into square integrable wavelets of constant shape. SIAM J Math Anal. 1984;15(4):723–736
  11. Johnstone I, Silverman B. Wavelet threshold estimators for data with correlated noise. J Royal Statist Soc. 1997;59(2):319–351
  12. Karthik R. ECG simulation using Matlab. <http://webscripts.softpedia.com/scriptDownload/ECG-simulation-using-MATLAB-Download-32785.html>.
  13. Krim H, Tucker D, Mallat S, Donoho D. On denoising and best signal representation. IEEE Trans Inform Theory. 1999;45(7):2225–2238
  14. Levine S, Gillen M. Diaphragmatic pressure waveform can predict electromyographic signs of diaphragmatic fatigue. J Appl Physiol. 1987;64(5):1681–1689
  15. Levine S, Gillen J, Weiser P, Gillen M, Kwatny E. Description and validation of an ECG removal procedure for EMGdi power spectrum analysis. J Appl Physiol. 1986;60(3):1073–1081
  16. Liang HL, Lin ZY, Wang H. Removal of ECG contamination from diaphragmatic EMG by nonlinear filtering. Nonlinear Anal. 2005;63:745–753
  17. Mallat S. A wavelet tour of signal processing. New York: Academic Press; 1998;
  18. Marque C, Bisch C, Dantas R, Elayoubi S, Brosse V, Perot C. Adaptive filtering for ECG rejection from surface EMG recordings. J Electromyogr Kinesiol. 2005;15(3):310–315
  19. Panagiotacopulos ND, Lee JS, Pope MH, Friesen K. Evaluation of EMG signals from rehabilitation patients with lower back pain using wavelets. J Electromyogr Kinesiol. 1998;8(4):269–278
  20. Pan Q, Zhang L, Dai G, Zhang H. Two denoising methods by wavelet transform. IEEE Trans Signal Proc. 1999;47(12):3401–3406
  21. Roberts C, Bartolo A, Dzwonczyk RR, Goldman E. Analysis of diaphragm EMG signals: comparison of gating vs. subtraction for removal of ECG contamination. J Appl Physiol. 1996;80(6):1892–1902
  22. Schweitzer TW, Fitzgerald JW, Bowden JA, Lynne-Davies P. Spectral analysis of human inspiratory diaphragmatic electromyograms. J Appl Physiol. 1979;46(1):152–165
  23. Stashuk DW. Simulation of electromyographic signals. J Electromyogr Kinesiol. 1993;3:157–173

PII: S1050-6411(09)00099-6

doi: 10.1016/j.jelekin.2009.07.007

Journal of Electromyography and Kinesiology
Volume 20, Issue 3 , Pages 542-549 , June 2010