Journal of Electromyography and Kinesiology
Volume 17, Issue 1 , Pages 90-101, February 2007

Reliability of techniques to assess human neuromuscular function in vivo

Musculoskeletal Research Laboratory, Department of Exercise Science, Syracuse University, 820 Comstock Avenue, Room 201, Syracuse, NY 13244, USA

Received 2 September 2005; received in revised form 21 November 2005; accepted 28 November 2005. published online 23 January 2006.

Abstract 

The purpose of this study was to comprehensively evaluate the reliability of a large number of commonly utilized experimental tests of in vivo human neuromuscular function separated by 4-weeks. Numerous electrophysiological parameters (i.e., voluntary and evoked electromyogram [EMG] signals), contractile properties (i.e., evoked forces and rates of force development and relaxation), muscle morphology (i.e., MRI-derived cross-sectional area [CSA]) and performance tasks (i.e., steadiness and time to task failure) were assessed from the plantarflexor muscle group in 17 subjects before and following 4-weeks where they maintained their normal lifestyle. The reliability of the measured variables had wide-ranging levels of consistency, with coefficient of variations (CV) ranging from ∼2% to 20%, and intraclass correlation coefficients (ICC) between 0.53 and 0.99. Overall, we observed moderate to high-levels of reliability in the vast majority of the variables we assessed (24 out of the 29 had ICC>0.70 and CV<15%). The variables demonstrating the highest reliability were: CSA (ICC=0.93–0.98), strength (ICC=0.97), an index of nerve conduction velocity (ICC=0.95), and H-reflex amplitude (ICC=0.93). Conversely, the variables demonstrating the lowest reliability were: the amplitude of voluntary EMG signal (ICC=0.53–0.88), and the time to task failure of a sustained submaximal contraction (ICC=0.64). Additionally, relatively little systematic bias (calculated through the limits of agreement) was observed in these measures over the repeat sessions. In conclusion, while the reliability differed between the various measures, in general it was rather high even when the testing sessions are separated by a relatively long duration of time.

Keywords: Reliability, EMG, MRI, Evoked force, H-reflex

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S1050-6411(05)00151-3

doi:10.1016/j.jelekin.2005.11.008

Journal of Electromyography and Kinesiology
Volume 17, Issue 1 , Pages 90-101, February 2007